TrippLite TE600
Details
Tripp Lite's TE600 UPS System provides line-interactive voltage regulation and long lasting battery support for small business telephone systems, voicemail systems, personal computers and other communications, network and telecom applications.
600VA power handling capacity and large capacity battery system maintains continuous operation through power interruptions with over 1 hour runtime for many 32 line phone systems. Line interactive voltage regulation maintains normal 120 volt output levels during brownouts as low as 75 and overvoltages as high as 147, saving battery reserves for use only during complete power failures.
Unique design features 6 protected outlets (3 UPS supported & 3 surge-suppression only), diagnostic LEDs and a built-in serial port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of network and PC applications (part# 75-0195).
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 600 |
Output Watt Capacity (Watts) | 425 |
Nominal Output Voltage(s) Supported | 115V; 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output Voltage Regulation (Battery Mode) | 115V (+/- 5%) |
Output Receptacles | (6) 5-15R |
UPS Output Receptacles (Surge Suppression Only) | 3 UPS outlets, 3 surge-only outlets |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 12A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
UPS Input Cord Length (ft.) | 6 |
UPS Input Cord Length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 9 min. (600w) |
Half Load Runtime (min.) | 22 min. (300w) |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge | |
Battery Access | Battery access door |
VOLTAGE REGULATION | |
---|---|
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction | Input voltages between 93 and 107 are boosted by 14% |
Severe Undervoltage Correction | Input voltages between 75 and 92 are boosted by 30% |
LEDS ALARMS & SWITCHES | |
---|---|
LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
---|---|
UPS AC Suppression Joule Rating | 480 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression | Yes |
-
Leandro Wells review Review by Leandro Wells
Rating Being from Saginaw, Michigan makes it hard to find parts like the , but you guys had it ready to ship. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's TE600 UPS System provides line-interactive voltage regulation and long lasting battery support for small business telephone systems, voicemail systems, personal computers and other communications, network and telecom applications.
600VA power handling capacity and large capacity battery system maintains continuous operation through power interruptions with over 1 hour runtime for many 32 line phone systems. Line interactive voltage regulation maintains normal 120 volt output levels during brownouts as low as 75 and overvoltages as high as 147, saving battery reserves for use only during complete power failures.
Unique design features 6 protected outlets (3 UPS supported & 3 surge-suppression only), diagnostic LEDs and a built-in serial port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of network and PC applications (part# 75-0195).
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 600 |
Output Watt Capacity (Watts) | 425 |
Nominal Output Voltage(s) Supported | 115V; 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output Voltage Regulation (Battery Mode) | 115V (+/- 5%) |
Output Receptacles | (6) 5-15R |
UPS Output Receptacles (Surge Suppression Only) | 3 UPS outlets, 3 surge-only outlets |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 12A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
UPS Input Cord Length (ft.) | 6 |
UPS Input Cord Length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 9 min. (600w) |
Half Load Runtime (min.) | 22 min. (300w) |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge | |
Battery Access | Battery access door |
VOLTAGE REGULATION | |
---|---|
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction | Input voltages between 93 and 107 are boosted by 14% |
Severe Undervoltage Correction | Input voltages between 75 and 92 are boosted by 30% |
LEDS ALARMS & SWITCHES | |
---|---|
LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
---|---|
UPS AC Suppression Joule Rating | 480 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression | Yes |