TrippLite Power

TrippLite TE600

$399.00

In stock

SKU: TPT0104


The TrippLite TE600 ships factory direct to your door.

Details

Tripp Lite's TE600 UPS System provides line-interactive voltage regulation and long lasting battery support for small business telephone systems, voicemail systems, personal computers and other communications, network and telecom applications.

600VA power handling capacity and large capacity battery system maintains continuous operation through power interruptions with over 1 hour runtime for many 32 line phone systems. Line interactive voltage regulation maintains normal 120 volt output levels during brownouts as low as 75 and overvoltages as high as 147, saving battery reserves for use only during complete power failures.
Unique design features 6 protected outlets (3 UPS supported & 3 surge-suppression only), diagnostic LEDs and a built-in serial port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of network and PC applications (part# 75-0195).

OUTPUT

Output Volt Amp Capacity (VA)600
Output Watt Capacity (Watts)425
Nominal Output Voltage(s) Supported115V; 120V
Frequency Compatibility60 Hz
Output Voltage Regulation (Line Mode)-18%, +8%
Output Voltage Regulation (Battery Mode)115V (+/- 5%)
Output Receptacles(6) 5-15R
UPS Output Receptacles (Surge Suppression Only)3 UPS outlets, 3 surge-only outlets
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode)PWM sine wave

INPUT

Rated input current (Maximum Load)12A
Nominal Input Voltage(s) Supported120V AC
UPS Input Connection Type5-15P
UPS Input Cord Length (ft.)6
UPS Input Cord Length (m)1.8
Recommended Electrical Service15A 120V
Input PhaseSingle-Phase

BATTERY

Full Load Runtime (min.)9 min. (600w)
Half Load Runtime (min.)22 min. (300w)
DC System Voltage (VDC)12
Battery Recharge Rate (Included Batteries)Less than 6 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge
Battery AccessBattery access door

VOLTAGE REGULATION

Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage CorrectionInput voltages between 128 and 147 are reduced by 12%
Undervoltage CorrectionInput voltages between 93 and 107 are boosted by 14%
Severe Undervoltage CorrectionInput voltages between 75 and 92 are boosted by 30%

LEDS ALARMS & SWITCHES

LED Indicators4 LEDs indicate line power, battery power, overload and battery low/replace status
Audible AlarmAudible alarm indicates power-failure and low-battery conditions
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Switches2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating480
UPS AC Suppression Response TimeInstantaneous
EMI / RFI AC Noise SuppressionYes

Features

Details

Tripp Lite's TE600 UPS System provides line-interactive voltage regulation and long lasting battery support for small business telephone systems, voicemail systems, personal computers and other communications, network and telecom applications.

600VA power handling capacity and large capacity battery system maintains continuous operation through power interruptions with over 1 hour runtime for many 32 line phone systems. Line interactive voltage regulation maintains normal 120 volt output levels during brownouts as low as 75 and overvoltages as high as 147, saving battery reserves for use only during complete power failures.
Unique design features 6 protected outlets (3 UPS supported & 3 surge-suppression only), diagnostic LEDs and a built-in serial port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of network and PC applications (part# 75-0195).

OUTPUT

Output Volt Amp Capacity (VA)600
Output Watt Capacity (Watts)425
Nominal Output Voltage(s) Supported115V; 120V
Frequency Compatibility60 Hz
Output Voltage Regulation (Line Mode)-18%, +8%
Output Voltage Regulation (Battery Mode)115V (+/- 5%)
Output Receptacles(6) 5-15R
UPS Output Receptacles (Surge Suppression Only)3 UPS outlets, 3 surge-only outlets
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode)PWM sine wave

INPUT

Rated input current (Maximum Load)12A
Nominal Input Voltage(s) Supported120V AC
UPS Input Connection Type5-15P
UPS Input Cord Length (ft.)6
UPS Input Cord Length (m)1.8
Recommended Electrical Service15A 120V
Input PhaseSingle-Phase

BATTERY

Full Load Runtime (min.)9 min. (600w)
Half Load Runtime (min.)22 min. (300w)
DC System Voltage (VDC)12
Battery Recharge Rate (Included Batteries)Less than 6 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge
Battery AccessBattery access door

VOLTAGE REGULATION

Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage CorrectionInput voltages between 128 and 147 are reduced by 12%
Undervoltage CorrectionInput voltages between 93 and 107 are boosted by 14%
Severe Undervoltage CorrectionInput voltages between 75 and 92 are boosted by 30%

LEDS ALARMS & SWITCHES

LED Indicators4 LEDs indicate line power, battery power, overload and battery low/replace status
Audible AlarmAudible alarm indicates power-failure and low-battery conditions
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Switches2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating480
UPS AC Suppression Response TimeInstantaneous
EMI / RFI AC Noise SuppressionYes

Make An Offer