TrippLite Power

TrippLite SU6000RT3UHV

$5,150.00

In stock

SKU: TPT0106


The TrippLite SU6000RT3UHV ships factory direct to your door.

Details

Tripp Lite's SmartOnline SU6000RT3UHV on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.

In rack configuration, power module and battery pack occupy only 3 rack spaces each (6U total).
Large capacity 6000 VA / 4200 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240v AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types.
Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types. Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V7RT3U). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shudown, remote control and monitoring of UPS system and power data.

OUTPUT

Output Capacity DetailsSupports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less
Output Volt Amp Capacity (VA)6000
Output kVA Capacity (kVA)6
Output Watt Capacity (Watts)4200
Output kW Capacity (kW)4.2
Power Factor0.7
Crest Factor3:1
Nominal Output Voltage(s) Supported200V; 208V; 220V; 230V; 240V
Nominal Voltage DetailsVoltage selection via front panel LCD interface
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsOutput frequency matches input nominal on startup
Output Voltage Regulation (Line Mode)+/- 2%
Output Voltage Regulation (Economy Line Mode)+/- 10%
Output Voltage Regulation (Battery Mode)+/- 2%
Output ReceptaclesHardwire
Output Receptacle Backplate OptionsOptional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
Output Circuit Breakers40A double-pole
Output AC Waveform (AC Mode)Pure Sine wave
Output AC Waveform (Battery Mode)Pure Sine wave

INPUT

Rated input current (Maximum Load)30A
Nominal Input Voltage(s) Supported200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection TypeHardwire
UPS Input Connection DescriptionSupports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring; Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
Input Circuit Breakers40A double-pole
Recommended Electrical Service30A 208/220/230/240V
Input PhaseSingle-Phase

BATTERY

Full Load Runtime (min.)8 min. (4200w)
Half Load Runtime (min.)20 min. (2100w
  1. Brent Oliveri review Review by Brent Oliveri
    Rating

    We needed Part# in less than 3 days to Berkeley, California. Thanks for the fast service! (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: TrippLite SU6000RT3UHV

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Features

Details

Tripp Lite's SmartOnline SU6000RT3UHV on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.

In rack configuration, power module and battery pack occupy only 3 rack spaces each (6U total).
Large capacity 6000 VA / 4200 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240v AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types.
Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types. Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V7RT3U). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shudown, remote control and monitoring of UPS system and power data.

OUTPUT

Output Capacity DetailsSupports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less
Output Volt Amp Capacity (VA)6000
Output kVA Capacity (kVA)6
Output Watt Capacity (Watts)4200
Output kW Capacity (kW)4.2
Power Factor0.7
Crest Factor3:1
Nominal Output Voltage(s) Supported200V; 208V; 220V; 230V; 240V
Nominal Voltage DetailsVoltage selection via front panel LCD interface
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsOutput frequency matches input nominal on startup
Output Voltage Regulation (Line Mode)+/- 2%
Output Voltage Regulation (Economy Line Mode)+/- 10%
Output Voltage Regulation (Battery Mode)+/- 2%
Output ReceptaclesHardwire
Output Receptacle Backplate OptionsOptional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
Output Circuit Breakers40A double-pole
Output AC Waveform (AC Mode)Pure Sine wave
Output AC Waveform (Battery Mode)Pure Sine wave

INPUT

Rated input current (Maximum Load)30A
Nominal Input Voltage(s) Supported200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection TypeHardwire
UPS Input Connection DescriptionSupports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring; Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord
Input Circuit Breakers40A double-pole
Recommended Electrical Service30A 208/220/230/240V
Input PhaseSingle-Phase

BATTERY

Full Load Runtime (min.)8 min. (4200w)
Half Load Runtime (min.)20 min. (2100w

Reviews

  1. Brent Oliveri review Review by Brent Oliveri
    Rating

    We needed Part# in less than 3 days to Berkeley, California. Thanks for the fast service! (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: TrippLite SU6000RT3UHV

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Make An Offer

We are often running unadvertised sale prices, rebates & special offers. We invite you to make a reasonable counter-offer at any time for any item. Who knows? - this may be your lucky day! We'll do our best to help you any way we can.