TrippLite SU6000RT3U
Details
Tripp Lite's SU6000RT3U on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module, step-down transformer and battery pack occupy only 3 rack spaces each (9U total).
Large capacity 6000 VA / 4200 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240V and 120V AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types.
Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V7RT3U). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shudown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less |
Output Volt Amp Capacity (VA) | 6000 |
Output kVA Capacity (kVA) | 6 |
Output Watt Capacity (Watts) | 4200 |
Output kW Capacity (kW) | 4.2 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 120V; 208V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | Hardwire |
Output Receptacle Backplate Options | Optional backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord |
Output Circuit Breakers | 40A double-pole |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 30A |
Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
UPS Input Connection Type | Hardwire |
UPS Input Connection Description | 3 wire single phase input (L1, L2, G); optional, country-specific backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord |
Input Circuit Breakers | 40A double-pole |
Recommended Electrical Service | 30A 208V or 240V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (4200w) |
Half Load Runtime (min.) | 20 min. (2100w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
-
Gary Lowery review Review by Gary Lowery
Rating Just trying to get repair parts in Walnut Creek, California is not easy, but I located the , but thanks to your company we got them FAST. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SU6000RT3U on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module, step-down transformer and battery pack occupy only 3 rack spaces each (9U total).
Large capacity 6000 VA / 4200 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240V and 120V AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types.
Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V7RT3U). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shudown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less |
Output Volt Amp Capacity (VA) | 6000 |
Output kVA Capacity (kVA) | 6 |
Output Watt Capacity (Watts) | 4200 |
Output kW Capacity (kW) | 4.2 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 120V; 208V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | Hardwire |
Output Receptacle Backplate Options | Optional backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord |
Output Circuit Breakers | 40A double-pole |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 30A |
Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
UPS Input Connection Type | Hardwire |
UPS Input Connection Description | 3 wire single phase input (L1, L2, G); optional, country-specific backplates SUPDM12 (for 208v nominal), SUPDM14 (for 240v nominal), SUPDM16 (for 208v nominal) add low and high voltage outlets, plus L6-30P input cord |
Input Circuit Breakers | 40A double-pole |
Recommended Electrical Service | 30A 208V or 240V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (4200w) |
Half Load Runtime (min.) | 20 min. (2100w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |