TrippLite SU5000RT3UHV
Details
5000VA online, double-conversion UPS for server, network and telecommunications equipment.
Uninterruptible Power Supply (UPS) maintains battery derived AC output during blackouts with active, full-time power conditioning / Fault tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions.
3U power module and 2U battery pack installs in 5 rack spaces / Full time sine wave output within 2% of selectable 200/208/220/230/240V AC / Corrects brownouts to 156 and overvoltages to 276V / Frequency regulation locks output power to 50/60Hz (+/-0.2%) .
Expandable runtime with optional rackmount external battery packs / Double conversion UPS converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types / Network grade AC surge and noise suppression / Network management interfaces include 2 DB9 ports and SNMPWEBCARD slot .
Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once / Includes PowerAlert monitoring software and complete cabling / Emergency Power Off (EPO) interface / Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions / Audible alarm / Self test / 4 post rackmount accessories / 2-9USTAND and 2POSTRMKIT accessories available / L6-30P plug-in connection / Built-in L6-30 & L6-20 outlets / Power Distribution Unit (PDU) options supported / Field replaceable, hot swappable external battery packs / Attractive all-black UPS design.
Two year warranty with $250,000 connected equipment insurance
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA Capacity (kVA) | 5 |
Output Watt Capacity (Watts) | 3500 |
Output kW Capacity (kW) | 3.5 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (2) L6-20R; (2) L6-30R |
Output Circuit Breakers | 20A double-pole breaker protects L6-20R outlets, L6-30R outlets are unbreakered |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 24A (208V), 21A (240V) |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
UPS Input Connection Type | L6-30P |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 30A 208/240V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (3500w) |
Half Load Runtime (min.) | 20 min. (1750w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
-
Chase Conway review Review by Chase Conway
Rating We love how you shipped the and we needed it there in a hurry shipping to Frankfort, Kentucky. It came fast. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
5000VA online, double-conversion UPS for server, network and telecommunications equipment.
Uninterruptible Power Supply (UPS) maintains battery derived AC output during blackouts with active, full-time power conditioning / Fault tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions.
3U power module and 2U battery pack installs in 5 rack spaces / Full time sine wave output within 2% of selectable 200/208/220/230/240V AC / Corrects brownouts to 156 and overvoltages to 276V / Frequency regulation locks output power to 50/60Hz (+/-0.2%) .
Expandable runtime with optional rackmount external battery packs / Double conversion UPS converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types / Network grade AC surge and noise suppression / Network management interfaces include 2 DB9 ports and SNMPWEBCARD slot .
Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once / Includes PowerAlert monitoring software and complete cabling / Emergency Power Off (EPO) interface / Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions / Audible alarm / Self test / 4 post rackmount accessories / 2-9USTAND and 2POSTRMKIT accessories available / L6-30P plug-in connection / Built-in L6-30 & L6-20 outlets / Power Distribution Unit (PDU) options supported / Field replaceable, hot swappable external battery packs / Attractive all-black UPS design.
Two year warranty with $250,000 connected equipment insurance
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA Capacity (kVA) | 5 |
Output Watt Capacity (Watts) | 3500 |
Output kW Capacity (kW) | 3.5 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (2) L6-20R; (2) L6-30R |
Output Circuit Breakers | 20A double-pole breaker protects L6-20R outlets, L6-30R outlets are unbreakered |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 24A (208V), 21A (240V) |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
UPS Input Connection Type | L6-30P |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 30A 208/240V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (3500w) |
Half Load Runtime (min.) | 20 min. (1750w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
Reviews
-
Chase Conway review Review by Chase Conway
Rating We love how you shipped the and we needed it there in a hurry shipping to Frankfort, Kentucky. It came fast. (Posted on 5/6/2019)