TrippLite SU3000RTXL3UHV
Details
Tripp Lite's high voltage Smart Online SU3000RTXL3UHV on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges.
Multi-use form factor occupies only 3 rack spaces (3U) in standard 19 inch rackmount configuration and includes tower stands to support upright placement. Large capacity 3kVA / 2400 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at selectable 200/208/220/230/240V AC (+/-2%) output.
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all high-voltage equipment types.
Includes 6 outlets arranged in two individually switchable load banks plus 2 L6-20 outlets. These outlet banks can be independently controlled via software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP72V122U).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's WatchDog Service Monitoring/Reboot Software.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds |
Output Volt Amp Capacity (VA) | 3000 |
Output kVA Capacity (kVA) | 3 |
Output Watt Capacity (Watts) | 2400 |
Output kW Capacity (kW) | 2.4 |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 240V |
Nominal Voltage Details | 208V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 6-15/20R; (2) L6-20R |
Load Management Receptacles | Two switchable 6-15/20R load banks (bank 1 - two outlets, bank 2 - four outlets) |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 14.9A (200V), 14.3A (208V), 13.1A (220V), 12.1A (240V) |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 240V AC |
UPS Input Connection Type | L6-20P |
Input Circuit Breakers | 25A double pole |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 5 min. (2400w) |
Half Load Runtime (min.) | 14 min. (1200w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
-
Glen Sweeney review Review by Glen Sweeney
Rating Your company was fast shipping the direct to Macon, Georgia. We will order again from your company. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's high voltage Smart Online SU3000RTXL3UHV on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges.
Multi-use form factor occupies only 3 rack spaces (3U) in standard 19 inch rackmount configuration and includes tower stands to support upright placement. Large capacity 3kVA / 2400 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at selectable 200/208/220/230/240V AC (+/-2%) output.
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all high-voltage equipment types.
Includes 6 outlets arranged in two individually switchable load banks plus 2 L6-20 outlets. These outlet banks can be independently controlled via software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP72V122U).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's WatchDog Service Monitoring/Reboot Software.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds |
Output Volt Amp Capacity (VA) | 3000 |
Output kVA Capacity (kVA) | 3 |
Output Watt Capacity (Watts) | 2400 |
Output kW Capacity (kW) | 2.4 |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 240V |
Nominal Voltage Details | 208V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 6-15/20R; (2) L6-20R |
Load Management Receptacles | Two switchable 6-15/20R load banks (bank 1 - two outlets, bank 2 - four outlets) |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 14.9A (200V), 14.3A (208V), 13.1A (220V), 12.1A (240V) |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 240V AC |
UPS Input Connection Type | L6-20P |
Input Circuit Breakers | 25A double pole |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 5 min. (2400w) |
Half Load Runtime (min.) | 14 min. (1200w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |