TrippLite SU2200XLA
Details
Tripp Lite's Smart Online SU2200XL on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in an attractive all-black upright tower format.
Large capacity 2.2kVA / 1600 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at 120V AC (+/-2%).
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types. Includes 7 UPS supported outlets with two individually switchable load banks that can be independently controlled via software interface to selectively reboot remote equipment, or automatically shed less critical loads to extend battery runtime for the most critical equipment. Battery support can be extended with the addition of multiple external battery packs (part# BP72V9).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's WatchDog Service Monitoring/Rebooting Software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 2200 |
Output kVA Capacity (kVA) | 2.2 |
Output Watt Capacity (Watts) | 1600 |
Output kW Capacity (kW) | 1.6 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 110V; 120V |
Nominal Voltage Details | 120V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 5-15/20R; (1) L5-20R |
Load Management Receptacles | Two switchable three-outlet 5-15/20R load banks |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 16A (120V), 17.6A (110V) |
Nominal Input Voltage(s) Supported | 110V AC; 120V AC |
UPS Input Connection Type | 5-20P |
Input Circuit Breakers | 30A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.5 min. (1600w) |
Half Load Runtime (min.) | 14 min. (800w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
-
Donnie Barreras review Review by Donnie Barreras
Rating Just trying to get repair parts in Tullahoma, Tennessee is not easy, but I located the , but thanks to your company we got them FAST. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's Smart Online SU2200XL on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in an attractive all-black upright tower format.
Large capacity 2.2kVA / 1600 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at 120V AC (+/-2%).
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types. Includes 7 UPS supported outlets with two individually switchable load banks that can be independently controlled via software interface to selectively reboot remote equipment, or automatically shed less critical loads to extend battery runtime for the most critical equipment. Battery support can be extended with the addition of multiple external battery packs (part# BP72V9).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's WatchDog Service Monitoring/Rebooting Software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 2200 |
Output kVA Capacity (kVA) | 2.2 |
Output Watt Capacity (Watts) | 1600 |
Output kW Capacity (kW) | 1.6 |
Power Factor | 0.7 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 110V; 120V |
Nominal Voltage Details | 120V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 5-15/20R; (1) L5-20R |
Load Management Receptacles | Two switchable three-outlet 5-15/20R load banks |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 16A (120V), 17.6A (110V) |
Nominal Input Voltage(s) Supported | 110V AC; 120V AC |
UPS Input Connection Type | 5-20P |
Input Circuit Breakers | 30A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.5 min. (1600w) |
Half Load Runtime (min.) | 14 min. (800w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
Reviews
-
Donnie Barreras review Review by Donnie Barreras
Rating Just trying to get repair parts in Tullahoma, Tennessee is not easy, but I located the , but thanks to your company we got them FAST. (Posted on 5/6/2019)