TrippLite SU1500RTXL2UA
Details
Tripp Lite's SmartOnLine SU1500RTXL2U on-line, double conversion UPS protects critical server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges.
Multi-use form factor occupies only 2 rack spaces (2U) in standard 19 inch rackmount configuration and includes tower stands and removable rack hardware to support tower and stacking applications.
Large capacity 1.5kVA / 1200 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at 120V AC (+/-2%).
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types.
Includes 6 outlets arranged in two individually switchable load banks that can be independently controlled via software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP48V212U).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's Watchdog system service software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1500 |
Output kVA Capacity (kVA) | 1.5 |
Output Watt Capacity (Watts) | 1200 |
Output kW Capacity (kW) | 1.2 |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
Nominal Voltage Details | 120V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 5-15R |
Load Management Receptacles | Two switchable 5-15R load banks (bank 1 - two outlets, bank 2 - four outlets) |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 12A |
Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 20A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 5 min. (1200w) |
Half Load Runtime (min.) | 14 min. (600w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
-
Britt Soto review Review by Britt Soto
Rating I saved about 3 hours getting the from you thanks! (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SmartOnLine SU1500RTXL2U on-line, double conversion UPS protects critical server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges.
Multi-use form factor occupies only 2 rack spaces (2U) in standard 19 inch rackmount configuration and includes tower stands and removable rack hardware to support tower and stacking applications.
Large capacity 1.5kVA / 1200 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at 120V AC (+/-2%).
Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types.
True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types.
Includes 6 outlets arranged in two individually switchable load banks that can be independently controlled via software interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP48V212U).
Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with Tripp Lite's Watchdog system service software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1500 |
Output kVA Capacity (kVA) | 1.5 |
Output Watt Capacity (Watts) | 1200 |
Output kW Capacity (kW) | 1.2 |
Power Factor | 0.8 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
Nominal Voltage Details | 120V default |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | (6) 5-15R |
Load Management Receptacles | Two switchable 5-15R load banks (bank 1 - two outlets, bank 2 - four outlets) |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 12A |
Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 20A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 5 min. (1200w) |
Half Load Runtime (min.) | 14 min. (600w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
Reviews
-
Britt Soto review Review by Britt Soto
Rating I saved about 3 hours getting the from you thanks! (Posted on 5/6/2019)