TrippLite SU10KRT3U
Details
Tripp Lite's Smart Online SU10KRT3U on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module, step-down transformer and battery pack occupy only 3 rack spaces each (9U total). Upright tower placement of entire system supported with included tower stands. Large capacity 10,000 VA / 7000 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240V and 120v AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.5 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types.
Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V10RT3U).
Includes slot for internal SNMP/web card, plus two DB9 enhanced serial and contact closure monitoring ports for unattended shudown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less |
Output Volt Amp Capacity (VA) | 10000 |
Output kVA Capacity (kVA) | 10 |
Output Watt Capacity (Watts) | 9000 |
Output kW Capacity (kW) | 9.0 |
Power Factor | 0.9 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 120V; 208V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
Frequency Compatibility Details | Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running) |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | Hardwire |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 54A (208V), 46.8A (240V) |
Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
UPS Input Connection Type | Hardwire |
UPS Input Connection Description | 3 wire single phase input (L1, L2, G) |
Recommended Electrical Service | 60A |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.3 min. (9000w) |
Half Load Runtime (min.) | 12.5 min. (4500w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
-
Barney Dickerson review Review by Barney Dickerson
Rating We needed Part# in less than 3 days to Belleville, Illinois. Thanks for the fast service! (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's Smart Online SU10KRT3U on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module, step-down transformer and battery pack occupy only 3 rack spaces each (9U total). Upright tower placement of entire system supported with included tower stands. Large capacity 10,000 VA / 7000 watt power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240V and 120v AC output voltages.
Frequency regulation locks output power to 50/60Hz (+/-0.5 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types.
Hardwire input and output connections support a variety of permanent or PDU style power connections. Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs (part# BP240V10RT3U).
Includes slot for internal SNMP/web card, plus two DB9 enhanced serial and contact closure monitoring ports for unattended shudown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less |
Output Volt Amp Capacity (VA) | 10000 |
Output kVA Capacity (kVA) | 10 |
Output Watt Capacity (Watts) | 9000 |
Output kW Capacity (kW) | 9.0 |
Power Factor | 0.9 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 120V; 208V; 240V |
Nominal Voltage Details | Voltage selection via front panel LCD interface |
Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
Frequency Compatibility Details | Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running) |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 2% |
Output Receptacles | Hardwire |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 54A (208V), 46.8A (240V) |
Nominal Input Voltage(s) Supported | 208V AC; 240V AC |
UPS Input Connection Type | Hardwire |
UPS Input Connection Description | 3 wire single phase input (L1, L2, G) |
Recommended Electrical Service | 60A |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.3 min. (9000w) |
Half Load Runtime (min.) | 12.5 min. (4500w) |
Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
Reviews
-
Barney Dickerson review Review by Barney Dickerson
Rating We needed Part# in less than 3 days to Belleville, Illinois. Thanks for the fast service! (Posted on 5/6/2019)