TrippLite SMART500RT1U
Details
Tripp Lite's SMART 500RT1U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.
Requires only one rack space (1U) in a 2 or 4 post rack, with included accessories for upright tower placement. Large internal batteries offer 17 minutes half load runtime and 5 minutes at full load.
Maintains regulated 120V nominal output without using battery power during brownouts as low as 90V. 500VA / 300 watt power handling capability is compatible with networking, telecom and other sensitive electronic applications.
Includes 6 UPS supported outlets with a single outlet load bank that can be individually controlled via software interface to reboot select equipment on demand or automatically shed less significant loads to extend battery runtime for more critical equipment.
Includes 1 surge-only outlet for peripherals not requiring battery backup. Supports simultaneous remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports.
Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency situation. Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status.
Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive all-black color scheme.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 500 |
Output Watt Capacity (Watts) | 300 |
Power Factor | 0.6 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -15%, +13% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (6) 5-15R |
UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 1 surge-only outlets |
Load Management Receptacles | One switchable single-outlet 5-15R load bank |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 5.6A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 15A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 4.5 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 3.2 min. (300w) |
Half Load Runtime (min.) | 14.6 min. (150w) |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | Less than 16 hours from 10% to 90% (typical, full load discharge) |
-
Ellsworth Wood review Review by Ellsworth Wood
Rating Your team was quick shipping the straight down to Mineola, New York. We like your service. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SMART 500RT1U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.
Requires only one rack space (1U) in a 2 or 4 post rack, with included accessories for upright tower placement. Large internal batteries offer 17 minutes half load runtime and 5 minutes at full load.
Maintains regulated 120V nominal output without using battery power during brownouts as low as 90V. 500VA / 300 watt power handling capability is compatible with networking, telecom and other sensitive electronic applications.
Includes 6 UPS supported outlets with a single outlet load bank that can be individually controlled via software interface to reboot select equipment on demand or automatically shed less significant loads to extend battery runtime for more critical equipment.
Includes 1 surge-only outlet for peripherals not requiring battery backup. Supports simultaneous remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports.
Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency situation. Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status.
Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive all-black color scheme.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 500 |
Output Watt Capacity (Watts) | 300 |
Power Factor | 0.6 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -15%, +13% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (6) 5-15R |
UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 1 surge-only outlets |
Load Management Receptacles | One switchable single-outlet 5-15R load bank |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 5.6A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 15A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 4.5 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 3.2 min. (300w) |
Half Load Runtime (min.) | 14.6 min. (150w) |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | Less than 16 hours from 10% to 90% (typical, full load discharge) |