TrippLite SMART5000RT3U
Details
Tripp Lite's SMART5000RT3U intelligent, line interactive UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module and battery pack occupy only 3 rack spaces (3U) each.
Large capacity 5000 VA / 4000 watt power module converts raw 208/240V AC input to fully regulated dual output 208/120 voltage for simultaneous protection of both high and low voltage equipment loads.
True sine wave output at all times offers guaranteed compatibility with all equipment types.
Includes a total of 14 outlets, 8 of which can be individually reset via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment.
Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs.
Includes slot for internal SNMP/web card, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports 4800 watts maximum with user supplied 50A input plug or hardwire input connection |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA Capacity (kVA) | 5 |
Output Watt Capacity (Watts) | 4000 |
Output kW Capacity (kW) | 4 |
Power Factor | 0.8 |
Nominal Output Voltage(s) Supported | 120V; 208V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | 208 & 120V (-10%, +20%) |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R |
Load Management Receptacles | Eight switchable single-outlet 5-15R load banks |
Output Circuit Breakers | 15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input |
Nominal Input Voltage(s) Supported | 208V AC |
UPS Input Connection Type | L6-30P |
Input Circuit Breakers | 30A double-pole |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 30A 208V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 16 min. (4000w) |
Half Load Runtime (min.) | 38 min. (2000w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
-
Curt Najar review Review by Curt Najar
Rating My company needed the and got to Herkimer, New York faster than I ever expected. Very helpful. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SMART5000RT3U intelligent, line interactive UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower / rackmount housing.
In rack configuration, power module and battery pack occupy only 3 rack spaces (3U) each.
Large capacity 5000 VA / 4000 watt power module converts raw 208/240V AC input to fully regulated dual output 208/120 voltage for simultaneous protection of both high and low voltage equipment loads.
True sine wave output at all times offers guaranteed compatibility with all equipment types.
Includes a total of 14 outlets, 8 of which can be individually reset via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical equipment.
Battery support can be extended indefinitely through the addition of external 3U rackmount battery packs.
Includes slot for internal SNMP/web card, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data.
OUTPUT | |
---|---|
Output Capacity Details | Supports 4800 watts maximum with user supplied 50A input plug or hardwire input connection |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA Capacity (kVA) | 5 |
Output Watt Capacity (Watts) | 4000 |
Output kW Capacity (kW) | 4 |
Power Factor | 0.8 |
Nominal Output Voltage(s) Supported | 120V; 208V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | 208 & 120V (-10%, +20%) |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (10) 5-15R; (2) 5-15/20R; (1) L14-30R; (1) L6-30R |
Load Management Receptacles | Eight switchable single-outlet 5-15R load banks |
Output Circuit Breakers | 15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input |
Nominal Input Voltage(s) Supported | 208V AC |
UPS Input Connection Type | L6-30P |
Input Circuit Breakers | 30A double-pole |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 30A 208V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 16 min. (4000w) |
Half Load Runtime (min.) | 38 min. (2000w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
Reviews
-
Curt Najar review Review by Curt Najar
Rating My company needed the and got to Herkimer, New York faster than I ever expected. Very helpful. (Posted on 5/6/2019)