TrippLite SMART2600RM2U
Details
Tripp Lite's SMART2600RM2U intelligent, line-interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges in a compact tower / rackmount housing.
UPS system occupies only 2U of rack space in any 2- or 4-post 19 inch rackmount application with a maximum depth of only 14.1 inches. Also supports upright tower use with 2USTAND accessory.
Large capacity 2600 VA / 2100 watt maximum rated UPS system offers 6 minutes runtime at full load and 18 minutes at half load during power failures.
Runtime is further expandable with the addition of BP48V242U or BP48V60RT3U external battery packs.
Line-interactive voltage regulation corrects brownouts as low as 75V and overvoltages as high as 147V to fully regulated 120V nominal output for smooth continuous operation of connected equipment. Includes a total of 9 outlets, 3 pairs of which can be individually powered off and back on via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical loads.
Battery runtime can be extended with external rackmount battery packs.
Includes slot for internal SNMP/web card, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data. Ships in attractive black color scheme. Compatible with Tripp Lite's PowerAlert and Watchdog service software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 2600 |
Output kVA Capacity (kVA) | 2.6 |
Output Watt Capacity (Watts) | 1920 |
Output kW Capacity (kW) | 1.92 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -14%, +6% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-20R |
Load Management Receptacles | Two switchable single-outlet 5-15R load banks |
Output Circuit Breakers | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 16A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-20P |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.6 min. (1920w) |
Half Load Runtime (min.) | 12.9 min. (960w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
-
Ambrose Conley review Review by Ambrose Conley
Rating I ordered the Received in 3 days. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SMART2600RM2U intelligent, line-interactive UPS protects server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges in a compact tower / rackmount housing.
UPS system occupies only 2U of rack space in any 2- or 4-post 19 inch rackmount application with a maximum depth of only 14.1 inches. Also supports upright tower use with 2USTAND accessory.
Large capacity 2600 VA / 2100 watt maximum rated UPS system offers 6 minutes runtime at full load and 18 minutes at half load during power failures.
Runtime is further expandable with the addition of BP48V242U or BP48V60RT3U external battery packs.
Line-interactive voltage regulation corrects brownouts as low as 75V and overvoltages as high as 147V to fully regulated 120V nominal output for smooth continuous operation of connected equipment. Includes a total of 9 outlets, 3 pairs of which can be individually powered off and back on via software interface to selectively reboot remote equipment or shed less critical loads to extend battery runtime for more critical loads.
Battery runtime can be extended with external rackmount battery packs.
Includes slot for internal SNMP/web card, plus 2 DB9 and 2 USB enhanced monitoring ports for unattended shutdown, remote control and monitoring of UPS system and power data. Ships in attractive black color scheme. Compatible with Tripp Lite's PowerAlert and Watchdog service software.
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 2600 |
Output kVA Capacity (kVA) | 2.6 |
Output Watt Capacity (Watts) | 1920 |
Output kW Capacity (kW) | 1.92 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -14%, +6% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-20R |
Load Management Receptacles | Two switchable single-outlet 5-15R load banks |
Output Circuit Breakers | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 16A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-20P |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3 |
Recommended Electrical Service | 20A 120V |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 4.6 min. (1920w) |
Half Load Runtime (min.) | 12.9 min. (960w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
Reviews
-
Ambrose Conley review Review by Ambrose Conley
Rating I ordered the Received in 3 days. (Posted on 5/6/2019)