OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1050 |
Output kVA Capacity (kVA) | 1 |
Output Watt Capacity (Watts) | 705 |
Power Factor | 0.7 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (6) 5-15R |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 6.7A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 12A |
UPS Input Cord Length (ft.) | 6 |
UPS Input Cord Length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Input Cord Length (ft.) | 6 |
Input Cord Length (m) | 1.8 |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (705w) |
Half Load Runtime (min.) | 23 min. (355w) |
DC System Voltage (VDC) | 18 |
Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge | |
Battery Access | Battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
---|---|
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction | Input voltages between 93 and 107 are boosted by 14% |
Severe Undervoltage Correction | Input voltages between 75 and 92 are boosted by 30% |
-
Earle Gates review Review by Earle Gates
Rating Being from Watkins Glen, New York made it hard to find parts like the . Thanks for shipping it out the same day! (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite's SMART1050 UPS System provides intelligent, line-interactive battery backup for networks and servers.
1,050 VA of battery backup allows you to work through short blackouts or safely shut down during longer ones.
The unit has 6 outlets, diagnostic LEDs and a built-in serial port that works with PowerAlert Software to provide automatic unattended shutdown.
Tripp Lite's PowerAlert Software is the only UPS software capable of managing every type and brand of UPS on your network, from every manufacturer.
$50,000 Ultimate Lifetime Insurance (USA & Canada Only). No warranty cards required for coverage!
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1050 |
Output kVA Capacity (kVA) | 1 |
Output Watt Capacity (Watts) | 705 |
Power Factor | 0.7 |
Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (6) 5-15R |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
INPUT | |
---|---|
Rated input current (Maximum Load) | 6.7A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 12A |
UPS Input Cord Length (ft.) | 6 |
UPS Input Cord Length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Input Cord Length (ft.) | 6 |
Input Cord Length (m) | 1.8 |
Input Phase | Single-Phase |
BATTERY | |
---|---|
Full Load Runtime (min.) | 8 min. (705w) |
Half Load Runtime (min.) | 23 min. (355w) |
DC System Voltage (VDC) | 18 |
Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge | |
Battery Access | Battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
---|---|
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction | Input voltages between 93 and 107 are boosted by 14% |
Severe Undervoltage Correction | Input voltages between 75 and 92 are boosted by 30% |