TrippLite IS500
Details
Tripp Lite Isolator series isolation transformers offer complete line isolation, continuous noise filtering and enhanced common mode surge suppression.
Internal low-impedance isolation transformer component with Faraday Shield offers 100% isolation from the input AC line. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.
Removes EMI/RFI noise, utility switching transients, backround spikes generated by other on-site loads and utility or lightning related surge conditions.
Additional surge suppression components placed at both the line input and transformer output combined with full line isolation offers continuous line filtering of a full range of power line noise in all modes.
Active transformer filtering with no wearable parts is uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500 offers 500 watts capacity with 4 widely spaced output receptacles, a 6-ft power cord, circuit breaker overload protection and lighted power switch.
Rugged all-metal unit housing ships ready for upright tower or wallmount placement in industrial, medical, office or network environment.
2 year manufacturers warranty.
OVERVIEW | |
---|---|
Efficiency | 96% |
Let-through Voltage (Combination Wave) | L-N: <130V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. B |
Let-through Voltage (Ring Wave) | L-N: <10V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. A |
Noise Suppression Rating | 33-65dB normal mode; > 80dB common mode |
Nominal Voltage / Frequency | 120V / 60Hz |
Over Current Protection | Yes, 4.5A circuit breaker |
Suppression Joule Rating | 680 Joules |
Surge Test Conditions | Per ANSI/IEEE C62.41 - (IEEE587) Cat. A & B test waveforms |
Total Harmonic Distortion | less than 1% |
VA / Watt Capacity | 500 |
Transformer Type | Low impedence isolation transformer |
OUTPUT | |
---|---|
Output Receptacles | (4) 5-15R |
Ouput Amp Capacity | 4.2 |
INPUT | |
---|---|
Input Cord Length (ft.) | 6 |
Input Cord Length (m) | 1.83 |
Input Plug Type | NEMA 5-15P |
-
Abraham Lynn review Review by Abraham Lynn
Rating Awesome how the went factory direct to Cranston, Rhode Island. Great job. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite Isolator series isolation transformers offer complete line isolation, continuous noise filtering and enhanced common mode surge suppression.
Internal low-impedance isolation transformer component with Faraday Shield offers 100% isolation from the input AC line. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.
Removes EMI/RFI noise, utility switching transients, backround spikes generated by other on-site loads and utility or lightning related surge conditions.
Additional surge suppression components placed at both the line input and transformer output combined with full line isolation offers continuous line filtering of a full range of power line noise in all modes.
Active transformer filtering with no wearable parts is uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500 offers 500 watts capacity with 4 widely spaced output receptacles, a 6-ft power cord, circuit breaker overload protection and lighted power switch.
Rugged all-metal unit housing ships ready for upright tower or wallmount placement in industrial, medical, office or network environment.
2 year manufacturers warranty.
OVERVIEW | |
---|---|
Efficiency | 96% |
Let-through Voltage (Combination Wave) | L-N: <130V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. B |
Let-through Voltage (Ring Wave) | L-N: <10V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. A |
Noise Suppression Rating | 33-65dB normal mode; > 80dB common mode |
Nominal Voltage / Frequency | 120V / 60Hz |
Over Current Protection | Yes, 4.5A circuit breaker |
Suppression Joule Rating | 680 Joules |
Surge Test Conditions | Per ANSI/IEEE C62.41 - (IEEE587) Cat. A & B test waveforms |
Total Harmonic Distortion | less than 1% |
VA / Watt Capacity | 500 |
Transformer Type | Low impedence isolation transformer |
OUTPUT | |
---|---|
Output Receptacles | (4) 5-15R |
Ouput Amp Capacity | 4.2 |
INPUT | |
---|---|
Input Cord Length (ft.) | 6 |
Input Cord Length (m) | 1.83 |
Input Plug Type | NEMA 5-15P |
Reviews
-
Abraham Lynn review Review by Abraham Lynn
Rating Awesome how the went factory direct to Cranston, Rhode Island. Great job. (Posted on 5/6/2019)