TrippLite IS1800HG
Details
Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression.
Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.
Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes.
Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch.
Rugged all-metal unit housing ships ready for upright tower placement in any industrial, medical, office or network environment.
OVERVIEW | |
---|---|
Efficiency | 96% |
Let-through Voltage (Combination Wave) | L-N: 250V L-G: 250V N-G: 0.5V |
Let-through Voltage (Ring Wave) | L-N: 20V L-G: 20V N-G: 0.5V |
Noise Suppression Rating | 35-65 DB |
Nominal Voltage / Frequency | 120V / 60Hz |
Over Current Protection | 1x thermal, 2 pole, 10 amp |
Shipping Weight | 58.00 lbs. / 26.31 kg |
Suppression Joule Rating | 1190 (1020 input / 170 output) |
Surge Test Conditions | Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms |
Total Harmonic Distortion | Less than 1% |
VA / Watt Capacity | 1800 |
Transformer Type | Hospital Grade, low impedance transformer-based line isolation transformer |
OUTPUT | |
---|---|
Output Receptacles | (6) 5-20R-HG |
Ouput Amp Capacity | 15 |
INPUT | |
---|---|
Input Cord Length (ft.) | 10 |
Input Cord Length (m) | 3.05 |
Input Plug Type | NEMA 5-20P-HG |
-
Dion Atkinson review Review by Dion Atkinson
Rating Our company wanted to thank Jesus for helping us find the part we needed very much. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression.
Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.
Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes.
Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch.
Rugged all-metal unit housing ships ready for upright tower placement in any industrial, medical, office or network environment.
OVERVIEW | |
---|---|
Efficiency | 96% |
Let-through Voltage (Combination Wave) | L-N: 250V L-G: 250V N-G: 0.5V |
Let-through Voltage (Ring Wave) | L-N: 20V L-G: 20V N-G: 0.5V |
Noise Suppression Rating | 35-65 DB |
Nominal Voltage / Frequency | 120V / 60Hz |
Over Current Protection | 1x thermal, 2 pole, 10 amp |
Shipping Weight | 58.00 lbs. / 26.31 kg |
Suppression Joule Rating | 1190 (1020 input / 170 output) |
Surge Test Conditions | Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms |
Total Harmonic Distortion | Less than 1% |
VA / Watt Capacity | 1800 |
Transformer Type | Hospital Grade, low impedance transformer-based line isolation transformer |
OUTPUT | |
---|---|
Output Receptacles | (6) 5-20R-HG |
Ouput Amp Capacity | 15 |
INPUT | |
---|---|
Input Cord Length (ft.) | 10 |
Input Cord Length (m) | 3.05 |
Input Plug Type | NEMA 5-20P-HG |
Reviews
-
Dion Atkinson review Review by Dion Atkinson
Rating Our company wanted to thank Jesus for helping us find the part we needed very much. (Posted on 5/6/2019)