TrippLite SMART1050SLT

TrippLite SMART1050SLT

TrippLite Power Products

  • $ 42900
  • Save $ 17000


Tripp Lite's SMART 1050SLT intelligent, line-interactive sine wave UPS system protects servers, networking accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges.

Large internal batteries offer 18 minutes half load runtime and 6 minutes fully loaded. 1050VA / 670 watt power handling capability and full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic applications.
Includes 8 protected NEMA 5-15R output receptacles. Supports simultaneous remote monitoring of UPS and site power conditions via built-in network accessory card slot, USB and DB9 serial monitoring ports. Optional SNMPWEBCARD accessory enables remote monitoring of UPS as a managed device via network management console applications.
Communications interfaces support messaging of UPS and line power status, plus output power control for scheduled or immediate reboot of all connected devices at once. Includes PowerAlert UPS monitoring and unattended shutdown software with management support for an unlimited number of network UPS systems. Free PowerAlert enterprise management software is also available for select opportunities.
Built-in audible alarm and 15 LEDs provide graphical readout of line power, battery power, battery charge level, load level, plus AVR boost and trim operational status information. Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges. Attractive, black tower housing in rugged all-metal enclosure.

OUTPUT

Output Volt Amp Capacity (VA) 1050
Output kVA Capacity (kVA) 1
Output Watt Capacity (Watts) 650
Power Factor 0.6
Nominal Output Voltage(s) Supported 100V; 110V; 120V
Nominal Voltage Details 120V default (voltage selection via back panel switches)
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) -13%, + 15%
Output Voltage Regulation (Battery Mode) +/- 5%
Output Receptacles (8) 5-15R
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 6.1A (120V), 6.6A (110V), 7.2A (100V)
Nominal Input Voltage(s) Supported 100V AC; 110V AC; 120V AC
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
Recommended Electrical Service 15A 120V
Input Phase Single-Phase

BATTERY

Full Load Runtime (min.) 7 min. (650w)
Half Load Runtime (min.) 19 min. (325w)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)