60/250 - kW/amps in 1-phase
60/208 - kW/amps 3-phase 120/208
60/181 - kW/amps 3-phase 120/240
60/90 - kW/amps 3-phase 277/480

GENERATOR SPECIFICATIONS
Manufacturer Marathon Electric Generators
Model & Type 361CSL1613 4 Pole, 4 Lead, Single Phase
. 361CSL1602 4 Pole, 12 Lead re-connectable, Three Phase
Exciter .Brushless, shunt excited
Voltage Regulator .Solid State, HZ/Volts
Voltage Regulation 1/2%, No load to full load
Frequency Field convertible, 60 HZ to 50 HZ
Frequency Regulation . 1/2% (1/2 cycle, no load to full load)
Unbalanced Load Capability .100% of standby amps
Total Stator and Load Insulation .Class H, 180 deg C
Temperature Rise . 130 deg C R/R, standby rating @ 40 deg C amb.
1 Motor Starting @ 30% Voltage Dip (240V) 128 kVA
3 Motor Starting @ 30% Voltage Dip (208-240V) .150 kVA
3 Motor Starting @ 30% Voltage Dip (480V) 200 kVA
Bearing . 1, Pre-lubed and sealed
Coupling .Direct flexible disc.
Total Harmonic Distortion . Max 31/2% (MIL-STD705B)
Telephone Interference Factor Max 50 (NEMA MG1-22)
Deviation Factor . Max 5% (MIL-STD 405B)
Ltd. Warranty Period 24 Months from date of start-up or
.1000 hours use, first to occur.

ENGINE
Manufacturer . John Deere
Model and Type 5030HF285, 4 cycle, liquid Cooled
Aspiration Turbocharged
Cylinder Arrangement .5 Cylinders, In-Line
Displacement Cu. In. (Liters) .186(3.05)
Bore & Stroke In. (Cm.) .3.4 x 4.1 (8.6 x 10.5)
Compression Ratio 18.2:1
Main Bearings & Style . 6, Replaceable Inserts
Cylinder Head .Cast Iron
Pistons 5, Aluminum Alloy
Crankshaft Ductile Iron
Exhaust Valve Stainless Steel
Governor JDEC, Electronic Level, EUP
Frequency Regulation 1/4%
Air Cleaner .Dry, Replaceable Cartridge
Engine Speed .1800 rpm
Max Power, bhp (kwm) Standby 97 (73)
BMEP: psi (kpa) Standby . 228 (1569)
Ltd. Warranty Period . 24 months or 2000 hrs, first to occur

Model Number: SPJD-600
Power Type: 120/240 Volt 1 PH 60 HZ
Horsepower HP: John Deere 99 bhp
Fuel Type: Diesel
Engine starter: 12VDC ELECTRIC ONLY
Max Wattage: 60 KW
Continuous Amps: 250 Amps
Height: 53"
Width: 42"
Length: 94"
Weight: 2556 lbs
  1. Dennis Palmisano review Review by Dennis Palmisano
    Rating

    I wanted to thank Alberto for helping me find the part I had to have. (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: Gillette 60kW Industrial Standby Diesel Generator SPJD-600 LVL-2

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Features

Details

Gillette SPJD-600

60/250 - kW/amps in 1-phase
60/208 - kW/amps 3-phase 120/208
60/181 - kW/amps 3-phase 120/240
60/90 - kW/amps 3-phase 277/480

GENERATOR SPECIFICATIONS
Manufacturer Marathon Electric Generators
Model & Type 361CSL1613 4 Pole, 4 Lead, Single Phase
. 361CSL1602 4 Pole, 12 Lead re-connectable, Three Phase
Exciter .Brushless, shunt excited
Voltage Regulator .Solid State, HZ/Volts
Voltage Regulation 1/2%, No load to full load
Frequency Field convertible, 60 HZ to 50 HZ
Frequency Regulation . 1/2% (1/2 cycle, no load to full load)
Unbalanced Load Capability .100% of standby amps
Total Stator and Load Insulation .Class H, 180 deg C
Temperature Rise . 130 deg C R/R, standby rating @ 40 deg C amb.
1 Motor Starting @ 30% Voltage Dip (240V) 128 kVA
3 Motor Starting @ 30% Voltage Dip (208-240V) .150 kVA
3 Motor Starting @ 30% Voltage Dip (480V) 200 kVA
Bearing . 1, Pre-lubed and sealed
Coupling .Direct flexible disc.
Total Harmonic Distortion . Max 31/2% (MIL-STD705B)
Telephone Interference Factor Max 50 (NEMA MG1-22)
Deviation Factor . Max 5% (MIL-STD 405B)
Ltd. Warranty Period 24 Months from date of start-up or
.1000 hours use, first to occur.

ENGINE
Manufacturer . John Deere
Model and Type 5030HF285, 4 cycle, liquid Cooled
Aspiration Turbocharged
Cylinder Arrangement .5 Cylinders, In-Line
Displacement Cu. In. (Liters) .186(3.05)
Bore & Stroke In. (Cm.) .3.4 x 4.1 (8.6 x 10.5)
Compression Ratio 18.2:1
Main Bearings & Style . 6, Replaceable Inserts
Cylinder Head .Cast Iron
Pistons 5, Aluminum Alloy
Crankshaft Ductile Iron
Exhaust Valve Stainless Steel
Governor JDEC, Electronic Level, EUP
Frequency Regulation 1/4%
Air Cleaner .Dry, Replaceable Cartridge
Engine Speed .1800 rpm
Max Power, bhp (kwm) Standby 97 (73)
BMEP: psi (kpa) Standby . 228 (1569)
Ltd. Warranty Period . 24 months or 2000 hrs, first to occur

Specifications

Model Number: SPJD-600
Power Type: 120/240 Volt 1 PH 60 HZ
Horsepower HP: John Deere 99 bhp
Fuel Type: Diesel
Engine starter: 12VDC ELECTRIC ONLY
Max Wattage: 60 KW
Continuous Amps: 250 Amps
Height: 53"
Width: 42"
Length: 94"
Weight: 2556 lbs

Reviews

  1. Dennis Palmisano review Review by Dennis Palmisano
    Rating

    I wanted to thank Alberto for helping me find the part I had to have. (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: Gillette 60kW Industrial Standby Diesel Generator SPJD-600 LVL-2

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Make An Offer

We are often running unadvertised sale prices, rebates & special offers. We invite you to make a reasonable counter-offer at any time for any item. Who knows? - this may be your lucky day! We'll do our best to help you any way we can.