Inverters

Exeltech XP125 48 Volt

$364.00

In stock

SKU: EXE0007

Free Shipping!


Exeltech’s XP series inverters provide the cleanest, best regulated sine wave output over the widest DC input of any inverter on the market today. They are extremely low in Total Distortion—specified to 2%, and typically better than 1.5%. Total Harmonic Distortion is typically 0.8% to 0.9%.

Details

  • DC INPUTS (12 VDC – 108 VDC): A 3′ non-terminated, two conductor power cord is provided. Insulation on the negative (-) conductor is black and insulation on the positive (+) conductor is red.
  • AC OUTPUTS: One NEMA-15 outlet (standard wall receptacle) is located on the Front Panel.
  • LOW BATT/THERM BUZZER: Produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, or if there is an over-temperature condition.
  • OVER VOLTAGE PROTECTION: If input voltage exceeds set limits, the inverter will immediately shut off, without warning. When input voltage returns to normal range, it will immediately restart. Since high over-voltages tend to have very fast edges, the inverter must shut down quickly to protect itself. This kind of fault usually occurs if the battery is suddenly disconnected from the system and the battery charger continues to supply current.
  • UNDER VOLTAGE PROTECTION: When battery voltage falls to within 2% to 4% of low line voltage, the LOW BATT/THERM buzzer will sound. If the condition continues without reducing load to the inverter or adding charge to the battery, the inverter will shut off. When voltage rises to approximately 95% of nominal battery voltage, it will turn back on and the alarm condition will clear. It can be manually reset by cycling the on/off switch. This will reset the protection circuitry and turn the inverter on at any voltage above minimum voltage.
  • OVER TEMPERATURE PROTECTION: The inverter is also protected against overheating. It will provide its full rated output up to the temperature listed in the specification sheet. If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter could overheat. If the LOWBATT/THERM buzzer sounds, immediate action is required or the inverter will shut down. Either reduce load, or provide more cooling in the immediate environment. If no action is taken, the inverter will likely shut down within two minutes. When the inverter shuts down, the alarm condition will persist.
Output DC Voltage: 48 Volts DC
Output Current: 3.1 A
Output power Type: Pure sine wave
Inverter type: Grid-Tied
Weight: 7
  1. Leigh Palmisano review Review by Leigh Palmisano
    Rating

    I wanted to thank Wallace for helping me find the part I needed to get things up and running again. (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: Exeltech XP125 48 Volt

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Features

Details

  • DC INPUTS (12 VDC – 108 VDC): A 3′ non-terminated, two conductor power cord is provided. Insulation on the negative (-) conductor is black and insulation on the positive (+) conductor is red.
  • AC OUTPUTS: One NEMA-15 outlet (standard wall receptacle) is located on the Front Panel.
  • LOW BATT/THERM BUZZER: Produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, or if there is an over-temperature condition.
  • OVER VOLTAGE PROTECTION: If input voltage exceeds set limits, the inverter will immediately shut off, without warning. When input voltage returns to normal range, it will immediately restart. Since high over-voltages tend to have very fast edges, the inverter must shut down quickly to protect itself. This kind of fault usually occurs if the battery is suddenly disconnected from the system and the battery charger continues to supply current.
  • UNDER VOLTAGE PROTECTION: When battery voltage falls to within 2% to 4% of low line voltage, the LOW BATT/THERM buzzer will sound. If the condition continues without reducing load to the inverter or adding charge to the battery, the inverter will shut off. When voltage rises to approximately 95% of nominal battery voltage, it will turn back on and the alarm condition will clear. It can be manually reset by cycling the on/off switch. This will reset the protection circuitry and turn the inverter on at any voltage above minimum voltage.
  • OVER TEMPERATURE PROTECTION: The inverter is also protected against overheating. It will provide its full rated output up to the temperature listed in the specification sheet. If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter could overheat. If the LOWBATT/THERM buzzer sounds, immediate action is required or the inverter will shut down. Either reduce load, or provide more cooling in the immediate environment. If no action is taken, the inverter will likely shut down within two minutes. When the inverter shuts down, the alarm condition will persist.

Specifications

Output DC Voltage: 48 Volts DC
Output Current: 3.1 A
Output power Type: Pure sine wave
Inverter type: Grid-Tied
Weight: 7

Reviews

  1. Leigh Palmisano review Review by Leigh Palmisano
    Rating

    I wanted to thank Wallace for helping me find the part I needed to get things up and running again. (Posted on 5/6/2019)

WRITE YOUR REVIEW

Write Your Own Review

You're reviewing: Exeltech XP125 48 Volt

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Make An Offer

We are often running unadvertised sale prices, rebates & special offers. We invite you to make a reasonable counter-offer at any time for any item. Who knows? - this may be your lucky day! We'll do our best to help you any way we can.