- DC INPUTS (12 VDC – 108 VDC): A 3′ non-terminated, two conductor power cord is provided. Insulation on the negative (-) conductor is black and insulation on the positive (+) conductor is red.
- AC OUTPUTS: One NEMA-15 outlet (standard wall receptacle) is located on the Front Panel.
- LOW BATT/THERM BUZZER: Produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, or if there is an over-temperature condition.
- OVER VOLTAGE PROTECTION: If input voltage exceeds set limits, the inverter will immediately shut off, without warning. When input voltage returns to normal range, it will immediately restart. Since high over-voltages tend to have very fast edges, the inverter must shut down quickly to protect itself. This kind of fault usually occurs if the battery is suddenly disconnected from the system and the battery charger continues to supply current.
- UNDER VOLTAGE PROTECTION: When battery voltage falls to within 2% to 4% of low line voltage, the LOW BATT/THERM buzzer will sound. If the condition continues without reducing load to the inverter or adding charge to the battery, the inverter will shut off. When voltage rises to approximately 95% of nominal battery voltage, it will turn back on and the alarm condition will clear. It can be manually reset by cycling the on/off switch. This will reset the protection circuitry and turn the inverter on at any voltage above minimum voltage.
- OVER TEMPERATURE PROTECTION: The inverter is also protected against overheating. It will provide its full rated output up to the temperature listed in the specification sheet. If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter could overheat. If the LOWBATT/THERM buzzer sounds, immediate action is required or the inverter will shut down. Either reduce load, or provide more cooling in the immediate environment. If no action is taken, the inverter will likely shut down within two minutes. When the inverter shuts down, the alarm condition will persist.
Output DC Voltage: | 24 Volts DC |
Output Current: | 6.1 A |
Output power Type: | Pure sine wave |
Inverter type: | Grid-Tied |
Weight: | 7 |
-
Gene Dougan review Review by Gene Dougan
Rating Just trying to get repair parts in Waterloo, Iowa is not easy, but I located the , but thanks to your company we got them FAST. (Posted on 5/6/2019)
WRITE YOUR REVIEW
Write Your Own Review
Features
Details
- DC INPUTS (12 VDC – 108 VDC): A 3′ non-terminated, two conductor power cord is provided. Insulation on the negative (-) conductor is black and insulation on the positive (+) conductor is red.
- AC OUTPUTS: One NEMA-15 outlet (standard wall receptacle) is located on the Front Panel.
- LOW BATT/THERM BUZZER: Produces an audible alarm if DC input voltage falls to a level within 2% to 4% of the low limit of inverter, or if there is an over-temperature condition.
- OVER VOLTAGE PROTECTION: If input voltage exceeds set limits, the inverter will immediately shut off, without warning. When input voltage returns to normal range, it will immediately restart. Since high over-voltages tend to have very fast edges, the inverter must shut down quickly to protect itself. This kind of fault usually occurs if the battery is suddenly disconnected from the system and the battery charger continues to supply current.
- UNDER VOLTAGE PROTECTION: When battery voltage falls to within 2% to 4% of low line voltage, the LOW BATT/THERM buzzer will sound. If the condition continues without reducing load to the inverter or adding charge to the battery, the inverter will shut off. When voltage rises to approximately 95% of nominal battery voltage, it will turn back on and the alarm condition will clear. It can be manually reset by cycling the on/off switch. This will reset the protection circuitry and turn the inverter on at any voltage above minimum voltage.
- OVER TEMPERATURE PROTECTION: The inverter is also protected against overheating. It will provide its full rated output up to the temperature listed in the specification sheet. If it is subjected to higher ambient temperatures or air circulation is blocked, the inverter could overheat. If the LOWBATT/THERM buzzer sounds, immediate action is required or the inverter will shut down. Either reduce load, or provide more cooling in the immediate environment. If no action is taken, the inverter will likely shut down within two minutes. When the inverter shuts down, the alarm condition will persist.
Specifications
Output DC Voltage: | 24 Volts DC |
Output Current: | 6.1 A |
Output power Type: | Pure sine wave |
Inverter type: | Grid-Tied |
Weight: | 7 |
Reviews
-
Gene Dougan review Review by Gene Dougan
Rating Just trying to get repair parts in Waterloo, Iowa is not easy, but I located the , but thanks to your company we got them FAST. (Posted on 5/6/2019)